Clúster Activo-Pasivo

Esta configuración se basa en dos servidores (NAS1 y NAS2), ambos con hardware similar y CentOS 7, que proporcionarán almacenamiento nfs de alta disponibilidad usando raids de software y drbd 8. Haremos uso de la caché de disco EnhanceIO con disco Intel NVME.

RED

Nombres de dispositivos de red NAS1

  • escola: interfaz de acceso
  • nas: almacenamiento exportado nfs
  • drbd: sincronización de almacenamiento
cat /etc/udev/rules.d/70-persistent-net.rules
SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="40:8d:5c:1e:0e:0c", ATTR{type}=="1", KERNEL=="e*", NAME="escola"
SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="a0:36:9f:6e:18:c0", ATTR{type}=="1", KERNEL=="e*", NAME="nas"
SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="a0:36:9f:6e:18:c2", ATTR{type}=="1", KERNEL=="e*", NAME="drbd"

Nombres de dispositivos de red NAS2

cat /etc/udev/rules.d/70-persistent-net.rules
SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="40:8d:5c:1e:1c:54", ATTR{type}=="1", KERNEL=="e*", NAME="escola"
SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="a0:36:9f:34:0a:c4", ATTR{type}=="1", KERNEL=="e*", NAME="nas"
SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="a0:36:9f:34:0a:c6", ATTR{type}=="1", KERNEL=="e*", NAME="drbd"

[root@nas2 network-scripts]# cat ifcfg-escola
TYPE="Ethernet"
BOOTPROTO="none"
DEFROUTE="yes"
IPV4_FAILURE_FATAL="no"
IPV6INIT="no"
IPV6_AUTOCONF="no"
IPV6_DEFROUTE="no"
IPV6_FAILURE_FATAL="no"
NAME="escola"
ONBOOT="yes"
HWADDR="40:8d:5c:1e:1c:54"
PEERDNS="yes"
PEERROUTES="yes"
IPV6_PEERDNS="no"
IPV6_PEERROUTES="no"

IPADDR="10.1.1.32"
PREFIX="24"
GATEWAY="10.1.1.199"
DNS1="10.1.1.200"
DNS2="10.1.1.201"
DOMAIN="escoladeltreball.org"

[root@nas2 network-scripts]# cat ifcfg-nas
TYPE="Ethernet"
BOOTPROTO="none"
DEFROUTE="no"
IPV4_FAILURE_FATAL="no"
IPV6INIT="no"
IPV6_AUTOCONF="no"
IPV6_DEFROUTE="no"
IPV6_FAILURE_FATAL="no"
NAME="drbd"
ONBOOT="yes"
HWADDR=A0:36:9F:34:0A:C4
PEERDNS="no"
PEERROUTES="no"
IPV6_PEERDNS="no"
IPV6_PEERROUTES="no"

IPADDR="10.1.2.32"
PREFIX="24"
MTU="9000"

[root@nas2 network-scripts]# cat ifcfg-drbd
TYPE="Ethernet"
BOOTPROTO="none"
DEFROUTE="no"
IPV4_FAILURE_FATAL="no"
IPV6INIT="no"
IPV6_AUTOCONF="no"
IPV6_DEFROUTE="no"
IPV6_FAILURE_FATAL="no"
NAME="drbd"
ONBOOT="yes"
HWADDR=A0:36:9F:34:0A:C6
PEERDNS="no"
PEERROUTES="no"
IPV6_PEERDNS="no"
IPV6_PEERROUTES="no"

IPADDR="10.1.3.32"
PREFIX="24"
MTU="9000"

Instalación base del SO

dnf update -y
vi /etc/hostname
dnf install ethtool pciutils fio smartmontools wget unzip tar mdadm net-tools

dnf install tuned
systemctl start tuned
systemctl enable tuned
tuned-adm profile throughput-performance

Herramienta de línea de comandos para intel NVMe y s3700

http://www.intel.com/support/ssdc/hpssd/sb/CS-035687.htm
wget https://downloadcenter.intel.com/downloads/eula/23931/Intel-Solid-State-Drive-Data-Center-Tool?httpDown=https%3A%2F%2Fdownloadmirror.intel.com%2F23931%2Feng%2FDataCenterTool_2_3_0_Linux.zip
unzip DataCenterTool_2_3_0_Linux.zip
rpm -Uvh isdct-2.3.0.400-13.x86_64.rpm

Comandos de ejemplo para verificar NVME

isdct show -intelssd
isdct show -sensor -intelssd 1

Inicializar discos

dd if=/dev/zero of=/dev/sdb bs=4k count=1024
dd if=/dev/zero of=/dev/sdc bs=4k count=1024
dd if=/dev/zero of=/dev/sdd bs=4k count=1024
dd if=/dev/zero of=/dev/sde bs=4k count=1024
dd if=/dev/zero of=/dev/sdf bs=4k count=1024
dd if=/dev/zero of=/dev/sdg bs=4k count=1024
dd if=/dev/zero of=/dev/nvme0n1 bs=4k count=1024
partprobe

También podríamos haber usado: wipefs -a /dev/xxx

Servidor de tiempo de red NTP

yum install ntp -y
systemctl start ntpd
systemctl status ntpd
systemctl enable ntpd

DISCOS DUROS:

Este es el resultado de lsblk:

NAME            MAJ:MIN RM   SIZE RO TYPE MOUNTPOINT
sda               8:0    0  37,3G  0 disk
├─sda1            8:1    0   200M  0 part /boot/efi
├─sda2            8:2    0   500M  0 part /boot
└─sda3            8:3    0  36,6G  0 part
  ├─fedora-root 253:0    0  32,9G  0 lvm  /
  └─fedora-swap 253:1    0   3,7G  0 lvm  [SWAP]
sdb               8:16   0   2,7T  0 disk
sdc               8:32   0   2,7T  0 disk
sdd               8:48   0   1,8T  0 disk
sde               8:64   0   1,8T  0 disk
sdf               8:80   0 465,8G  0 disk
sdg               8:96   0  93,2G  0 disk
nvme0n1         259:0    0 372,6G  0 disk

Particiones de discos duros

  • sdd & sde: 7200rpm, 1,8TB
  • sdb & sdc: 5400rpm, 2,7TB

Esquema que crearemos con raids (md) lvms y drbd. NOTA: Tenemos lvs por debajo y por encima de drbd. Eso nos permite cambiar el tamaño del esquema subyacente y también redistribuir el almacenamiento sobre drbd. También dividimos el almacenamiento para permitir mover recursos en ambos nodos.

sdd1---\
        md1--\           /---lvgroups (md1)-------drbd30------vg_groups-------lv_groups
sde1---/      \         /
               vgdata--x-----lvtemplates----------drbd20------vg_templates----lv_templates
sdb1---\      /         \
        md2--/           \---lvbases--------------drbd10------vg_bases--------lv_bases
sdc1---/                  \
                           \-lvoldgroups----------drbd35------vg_oldgroups----lv_oldgroups


nvme0n1p1-\                 /--lv_cachegroups-----drbd31------vgcache_groups-----lvcache_groups
           \               /
sdf1--------x----vgcache--x----lv_cachetemplates--drbd21------vgcache_templates--lvcache_templates
           /               \
sdg1------/                 \--lv_cachebases------drbd11------vgcache_bases------lvcache_bases

Y esta es la caché sobre el diseño anterior:

lv_groups----------\
                    EnhanceIO:groups--------->/vimet/groups
lvcache_groups-----/

lv_templates-------\
                    EnhanceIO:templates------>/vimet/templates
lvcache_templates--/

lv_bases-----------\
                    EnhanceIO:bases---------->/vimet/bases
lvcache_bases------/

Creación de particiones

Dejamos una pequeña partición al principio de los discos para realizar pruebas de io.

Con parted podemos verificar la alineación de las particiones:

print free
align-check opt 1

Creamos las particiones. Verificamos los sectores para asegurarnos de que comienzan al principio del sector de un disco. Esto maximizará io. Debe verificar sus discos con los comandos anteriores.

parted /dev/sdb mklabel gpt
parted /dev/sdc mklabel gpt
parted /dev/sdd mklabel gpt
parted /dev/sde mklabel gpt
parted /dev/sdf mklabel gpt
parted /dev/sdg mklabel gpt
parted /dev/nvme0n1 mklabel gpt
parted -a optimal /dev/sdb mkpart primary ext4 4096s 2980G
parted -a optimal /dev/sdb mkpart primary ext4 2980G 100%
parted -a optimal /dev/sdc mkpart primary ext4 4096s 2980GB
parted -a optimal /dev/sdc mkpart primary ext4 2980GB 100%
parted -a optimal /dev/sdd mkpart primary ext4 4096s 1980GB
parted -a optimal /dev/sdd mkpart primary ext4 1980GB 100%
parted -a optimal /dev/sde mkpart primary ext4 4096s 1980GB
parted -a optimal /dev/sde mkpart primary ext4 1980GB 100%
parted -a optimal /dev/sdf mkpart primary ext4 2048s 495G
parted -a optimal /dev/sdf mkpart primary ext4 495GB 100%
parted -a optimal /dev/sdg mkpart primary ext4 512 94GB
parted -a optimal /dev/sdg mkpart primary ext4 94GB 99GB
parted -a optimal /dev/sdg mkpart primary ext4 99GB 100%
parted -a optimal /dev/nvme0n1 mkpart primary ext4 512 395GB
parted -a optimal /dev/nvme0n1 mkpart primary ext4 395GB 100%

reboot recomendado

RAIDS

Los raids permitirán la primera redundancia en el sistema. Creamos raids de nivel 1 que proporcionarán 2x la velocidad de lectura y duplicación de datos.

mdadm --create /dev/md1 --level=1 --raid-devices=2 /dev/sdd1 /dev/sde1
mdadm --create /dev/md2 --level=1 --raid-devices=2 /dev/sdb1 /dev/sdc1
mdadm --detail --scan >> /etc/mdadm.conf

LVMs no agrupados (locales)

Filtrado de dispositivos

Necesitamos establecer los dispositivos donde lvm buscará las firmas de lvm.

filter = ["a|sd.*|", "a|nvme.*|", "a|md.*|", "a|drbd.*|", "r|.*|"]

Esquema pv/vg/lv (bajo drbd)

pvcreate /dev/md1
pvcreate /dev/md2

vgcreate -cn vgdata /dev/md1 /dev/md2
lvcreate -l 100%FREE -n lvgroups vgdata /dev/md1
lvcreate -L 1700G -n lvoldgroups vgdata /dev/md2
lvcreate -l 100%FREE -n lvtemplates vgdata /dev/md2

pvcreate /dev/nvme0n1p1
pvcreate /dev/sdf1
pvcreate /dev/sdg1
vgcreate vgcache /dev/nvme0n1p1 /dev/sdf1 /dev/sdg1
lvcreate -l 100%FREE -n lvcachebases vgcache /dev/sdg1
lvcreate -l 100%FREE -n lvcachetemplates vgcache /dev/sdg1
lvcreate -l 100%FREE -n lvcachegroups vgcache /dev/nvme0n1p1

DRBD

Instalar drbd 8

yum install drbd drbd-utils drbd-udev drbd-pacemaker -y
modprobe drbd
systemctl enable drbd
Crear archivos de configuración de drbd y recursos.

Archivos de configuración DRBD

[root@nas1 ~]# cat /etc/drbd.conf

# You can find an example in  /usr/share/doc/drbd.../drbd.conf.example

include "drbd.d/global_common.conf";
include "drbd.d/*.res";

[root@nas1 ~]# cat /etc/drbd.d/global_common.conf

# DRBD is the result of over a decade of development by LINBIT.
# In case you need professional services for DRBD or have
# feature requests visit http://www.linbit.com

global {
}

common {
        handlers {
                fence-peer "/usr/lib/drbd/crm-fence-peer.sh";
                after-resync-target "/usr/lib/drbd/crm-unfence-peer.sh";
        }

        startup {
        }

        options {
        }

        disk {
                #al-extents 3389;
                #disk-barrier no;
                #disk-flushes no;
                #fencing resource-and-stonith;
                fencing resource-only;
        }

        net {
                max-buffers 16000;
                max-epoch-size 16000;
                #unplug-watermark 16;
                #sndbuf-size 2048;
                allow-two-primaries;
                after-sb-0pri discard-zero-changes;
                after-sb-1pri discard-secondary;
                after-sb-2pri disconnect;
        }

        syncer {
         }
}

[root@nas1 ~]# cat /etc/drbd.d/bases.res

resource bases {
         startup {
                #become-primary-on both;
         }
        volume 0 {
                device    /dev/drbd11;
                disk      /dev/vgcache/lvcachebases;
                meta-disk internal;
        }

        volume 1 {
                device    /dev/drbd10;
                disk      /dev/vgdata/lvbases;
                meta-disk internal;
        }
    on nas1 {
         address   10.1.3.31:7810;
    }
    on nas2 {
         address   10.1.3.32:7810;
    }
}

[root@nas1 ~]# cat /etc/drbd.d/templates.res

resource templates {
         startup {
                #become-primary-on both;
         }
   volume 0 {
         device    /dev/drbd21;
         disk      /dev/vgcache/lvcachetemplates;
         meta-disk internal;
   }
   volume 1 {
         device    /dev/drbd20;
         disk      /dev/vgdata/lvtemplates;
         meta-disk internal;
   }
    on nas1 {
         address   10.1.3.31:7820;
    }
    on nas2 {
         address   10.1.3.32:7820;
    }
}

[root@nas1 ~]# cat /etc/drbd.d/groups.res

resource groups {
         startup {
                #become-primary-on both;
         }
        volume 0 {
                device    /dev/drbd31;
                disk      /dev/vgcache/lvcachegroups;
                meta-disk internal;
        }

        volume 1 {
                device    /dev/drbd30;
                disk      /dev/vgdata/lvgroups;
                meta-disk /dev/sdg3;
        }

        volume 2 {
                device    /dev/drbd35;
                disk      /dev/vgdata/lvoldgroups;
                meta-disk internal;
        }
    on nas1 {
         address   10.1.3.31:7830;
    }
    on nas2 {
         address   10.1.3.32:7830;
    }
}

Ahora podemos crear recursos drbd.

drbdadm create-md bases
drbdadm create-md templates
drbdadm create-md groups
drbdadm up bases
drbdadm up templates
drbdadm up grups
drbdadm primary bases --force
drbdadm primary templates --force
drbdadm primary grups --force

drbdadm disk-options --resync-rate=400M <resource>

LVM Volúmenes anidados (ahora sobre drbd)

Esta configuración de lvm debe hacerse en un solo nodo:

Grupos

pvcreate /dev/drbd30
pvcreate /dev/drbd31
vgcreate vgcache_groups /dev/drbd31
lvcreate -l 100%FREE -n lvcache_groups vgcache_groups
lvcreate -l 100%FREE -n lvcache_templates vgcache_templates
vgcreate vg_groups /dev/drbd20
lvcreate -l 100%FREE -n lv_groups vg_groups
vgchange -ay vg_groups

Plantillas

pvcreate /dev/drbd20
pvcreate /dev/drbd21
vgcreate vgcache_templates /dev/drbd21
lvcreate -l 100%FREE -n lvcache_templates vgcache_templates
vgcreate vg_templates /dev/drbd20
lvcreate -l 100%FREE -n lv_templates vg_templates
vgchange -ay vg_templates

Bases

pvcreate /dev/drbd10
pvcreate /dev/drbd11
vgcreate vgcache_bases /dev/drbd11
lvcreate -l 100%FREE -n lvcache_bases vgcache_bases
vgcreate vg_bases /dev/drbd10
lvcreate -l 100%FREE -n lv_bases vg_bases
vgchange -ay vg_templates

OldGroups

pvcreate /dev/drbd35
vgcreate vg_oldgroups /dev/drbd35
lvcreate -l 100%FREE -n lv_oldgroups vg_oldgroups

Sistema de archivos

mkfs.ext4 /dev/vg_bases/lv_bases
mkfs.ext4 /dev/vg_templates/lv_templates
mkfs.ext4 /dev/vg_groups/lv_groups
mkfs.ext4 /dev/vg_oldgroups/lv_oldgroups
** Ahora puede intentar montar lvs para verificar que todo está bien.

Caché de disco EnhanceIO

Primero lo instalamos:

dnf install kernel-devel gcc
git clone https://github.com/stec-inc/EnhanceIO.git
cd EnhanceIO/Driver/enhanceio
make && make install

cd /root/EnhanceIO/CLI
Aplicar parche para núcleos> 3:
diff --git a/CLI/eio_cli b/CLI/eio_cli
index 3453b35..a0b60c5 100755
--- a/CLI/eio_cli
+++ b/CLI/eio_cli
@@ -1,4 +1,4 @@
-#!/usr/bin/python
+#!/usr/bin/python2
 #
 # Copyright (C) 2012 STEC, Inc. All rights not specifically granted
 # under a license included herein are reserved
@@ -305,10 +305,12 @@ class Cache_rec(Structure):

        def do_eio_ioctl(self,IOC_TYPE):
                #send ioctl to driver
-               fd = open(EIODEV, "r")
+               libc = CDLL('libc.so.6')
+               fd = os.open (EIODEV, os.O_RDWR, 0400)
                fmt = ''
+               selfaddr = c_uint64(addressof(self))
                try:
-                       if ioctl(fd, IOC_TYPE, addressof(self)) == SUCCESS:
+                       if libc.ioctl(fd, IOC_TYPE, selfaddr) == SUCCESS:
                                return SUCCESS
                except Exception as e:
                        print e

Copiar binario a la carpeta de ruta e instalar módulos en el núcleo:

cp EnhanceIO/CLI/eio_cli /sbin

modprobe enhanceio
modprobe enhanceio_fifo  x
modprobe enhanceio_lru
modprobe enhanceio_rand  x

Instalación de módulos persistentes:

vi /etc/modules-load.d/enhanceio.conf
    enhanceio
    enhanceio_lru
Para detener el dispositivo de caché, debemos ponerlo en solo lectura y esperar hasta que todos los sectores sucios de nvme se transfieran a los discos duros rotativos.
eio_cli edit -c data -m ro
Evite las actualizaciones del núcleo, ya que romperán enhanceio y podría perder todos sus datos!.
vi /etc/dnf/dnf.conf
    exclude=kernel*
Debemos crear cachés SOLO en el nodo primario de drbd y copiar las reglas de udev creadas al otro nas. (/etc/udev/rules.d/94...):
eio_cli create -d /dev/vg_groups/lv_groups -s /dev/vgcache_groups/lvcache_groups -p lru -m wb -c groups
eio_cli create -d /dev/vg_templates/lv_templates -s /dev/vgcache_templates/lvcache_templates -p lru -m wb -c templates
eio_cli create -d /dev/vg_bases/lv_bases -s /dev/vgcache_bases/lvcache_bases -p lru -m wt -c bases
Verificar el estado de la caché:
eio_cli info
cat /proc/enhanceio/<cache_name>/stats

Clúster PACEMAKER

Pacemaker mantendrá nuestros recursos bajo monitoreo y los reiniciará en el otro nodo en caso de falla.

dnf install corosync pacemaker pcs -y
systemctl enable pcsd; systemctl enable corosync; systemctl enable pacemaker;
systemctl start pcsd;
#passwd hacluster  (habitual)
pcs cluster auth nas1 nas2  (hacluster/habitual)
pcs cluster setup --name vimet_cluster nas1 nas2
pcs cluster start --all
pcs status

pcs property set default-resource-stickiness=200
pcs property set no-quorum-policy=ignore

Para eliminar un clúster existente:

pcs cluster stop --all
pcs cluster destroy 
rm -rf /var/lib/pcsd/*
reboot

Agentes de cercado

Instalar agentes de cercado. Una configuración de pacemaker NO puede funcionar sin un dispositivo de cercado. Usamos el dispositivo stonith APC:

yum install python-pycurl fence-agents-apc fence-agents-apc-snmp -y

Definición de recursos de pacemaker para el agente de cercado (stonith):

pcs cluster cib fence_cfg
pcs -f fence_cfg stonith create stonith fence_apc_snmp params ipaddr=10.1.1.4 pcmk_host_list="nas1,nas2" pcmk_host_map="nas1:3;nas2:4" pcmk_host_check=static-list power_wait=5 inet4only debug=/var/log/stonith.log retry_on=10
pcs cluster cib-push fence_cfg

pcs property set stonith-enabled=true
pcs property set start-failure-is-fatal=false

Recursos DRBD

pcs cluster cib drbd_bases_cfg
pcs -f drbd_bases_cfg resource create drbd_bases ocf:linbit:drbd drbd_resource=bases op monitor interval=15s role=Master op monitor interval=30s role=Slave
pcs -f drbd_bases_cfg resource master drbd_bases-clone drbd_bases master-max=1 master-node-max=1 clone-max=2 clone-node-max=1 notify=true
pcs cluster cib-push drbd_bases_cfg

pcs cluster cib drbd_templates_cfg
pcs -f drbd_templates_cfg resource create drbd_templates ocf:linbit:drbd drbd_resource=templates op monitor interval=15s role=Master op monitor interval=30s role=Slave
pcs -f drbd_templates_cfg resource master drbd_templates-clone drbd_templates master-max=1 master-node-max=1 clone-max=2 clone-node-max=1 notify=true
pcs cluster cib-push drbd_templates_cfg

pcs cluster cib drbd_groups_cfg
pcs -f drbd_groups_cfg resource create drbd_groups ocf:linbit:drbd drbd_resource=groups op monitor interval=15s role=Master op monitor interval=30s role=Slave
pcs -f drbd_groups_cfg resource master drbd_groups-clone drbd_groups master-max=1 master-node-max=1 clone-max=2 clone-node-max=1 notify=true
pcs cluster cib-push drbd_groups_cfg

Recursos LVM

pcs resource create lv_bases ocf:heartbeat:LVM volgrpname=vg_bases op monitor interval=30s
pcs resource create lv_templates ocf:heartbeat:LVM volgrpname=vg_templates op monitor interval=30s
pcs resource create lv_groups ocf:heartbeat:LVM volgrpname=vg_groups op monitor interval=30s
pcs resource create lv_oldgroups ocf:heartbeat:LVM volgrpname=vg_oldgroups op monitor interval=30s
pcs resource create lvcache_bases ocf:heartbeat:LVM volgrpname=vgcache_bases op monitor interval=30s
pcs resource create lvcache_templates ocf:heartbeat:LVM volgrpname=vgcache_templates op monitor interval=30s
pcs resource create lvcache_groups ocf:heartbeat:LVM volgrpname=vgcache_groups op monitor interval=30s

Sistema de archivos ext4 y puntos de montaje

pcs resource create ext4_bases Filesystem device="/dev/vg_bases/lv_bases" directory="/vimet/bases" fstype="ext4" "options=defaults,noatime,nodiratime,noquota" op monitor interval=10s
pcs resource create ext4_templates Filesystem device="/dev/vg_templates/lv_templates" directory="/vimet/templates" fstype="ext4" "options=defaults,noatime,nodiratime,noquota" op monitor interval=10s
pcs resource create ext4_groups Filesystem device="/dev/vg_groups/lv_groups" directory="/vimet/groups" fstype="ext4" "options=defaults,noatime,nodiratime,noquota" op monitor interval=10s
pcs resource create ext4_oldgroups Filesystem device="/dev/vg_oldgroups/lv_oldgroups" directory="/vimet/oldgroups" fstype="ext4" "options=defaults,noatime,nodiratime,noquota" op monitor interval=10s

Servidor NFS

Versión 4

NFS: servidor y raíz

pcs cluster cib nfsserver_cfg
pcs -f nfsserver_cfg resource create nfs-daemon systemd:nfs-server \
nfs_shared_infodir=/nfsshare/nfsinfo nfs_no_notify=true op monitor interval=30s \
--group nfs_server
pcs -f nfsserver_cfg resource create nfs-root exportfs \
clientspec=10.1.0.0/255.255.0.0 \
options=rw,crossmnt,async,wdelay,no_root_squash,no_subtree_check,sec=sys,rw,secure,no_root_squash,no_all_squash \
directory=/vimet \
fsid=0 \
--group nfs_server
pcs cluster cib-push nfsserver_cfg
pcs resource clone nfs_server master-max=2 master-node-max=1 clone-max=2 clone-node-max=1 on-fail=restart notify=true resource-stickiness=0

NFS: Exportaciones

pcs cluster cib exports_cfg
pcs -f exports_cfg resource create nfs_bases exportfs \
clientspec=10.1.0.0/255.255.0.0 \
wait_for_leasetime_on_stop=true \
options=rw,mountpoint,async,wdelay,no_root_squash,no_subtree_check,sec=sys,rw,secure,no_root_squash,no_all_squash directory=/vimet/bases \
fsid=11 \
op monitor interval=30s

pcs -f exports_cfg resource create nfs_templates exportfs \
clientspec=10.1.0.0/255.255.0.0 \
wait_for_leasetime_on_stop=true \
options=rw,mountpoint,async,wdelay,no_root_squash,no_subtree_check,sec=sys,rw,secure,no_root_squash,no_all_squash directory=/vimet/templates \
fsid=20 \
op monitor interval=30s

pcs -f exports_cfg resource create nfs_groups exportfs \
clientspec=10.1.0.0/255.255.0.0 \
wait_for_leasetime_on_stop=true \
options=rw,async,mountpoint,wdelay,no_root_squash,no_subtree_check,sec=sys,rw,secure,no_root_squash,no_all_squash directory=/vimet/groups \
fsid=30 \
op monitor interval=30s

pcs -f exports_cfg resource create nfs_oldgroups exportfs \
clientspec=10.1.0.0/255.255.0.0 \
wait_for_leasetime_on_stop=true \
options=rw,async,mountpoint,wdelay,no_root_squash,no_subtree_check,sec=sys,rw,secure,no_root_squash,no_all_squash directory=/vimet/oldgroups \
fsid=35 \
op monitor interval=30s
pcs cluster cib-push exports_cfg

IPs flotantes

Estas IPs "moverán" siempre con los recursos asignados.

pcs resource create IPbases ocf:heartbeat:IPaddr2 ip=10.1.2.210 cidr_netmask=32 nic=nas:0  op monitor interval=30 
pcs resource create IPtemplates ocf:heartbeat:IPaddr2 ip=10.1.2.211 cidr_netmask=32 nic=nas:0  op monitor interval=30 
pcs resource create IPgroups ocf:heartbeat:IPaddr2 ip=10.1.2.212 cidr_netmask=32 nic=nas:0 op monitor interval=30
pcs resource create IPvbases ocf:heartbeat:IPaddr2 ip=10.1.1.28 cidr_netmask=32 nic=escola:0 op monitor interval=30
pcs resource create IPvtemplates ocf:heartbeat:IPaddr2 ip=10.1.1.29 cidr_netmask=32 nic=escola:0 op monitor interval=30
pcs resource create IPvgroups ocf:heartbeat:IPaddr2 ip=10.1.1.30 cidr_netmask=32 nic=escola:0 op monitor interval=30

Grupos y restricciones

Los grupos permitirán iniciar y detener recursos en orden. Las restricciones permitirán definiciones de restricciones.

bases

pcs resource group add bases \
    lvcache_bases lv_bases ext4_bases nfs_bases IPbases IPvbases 

pcs constraint order \
    promote drbd_bases-clone then bases INFINITY \
    require-all=true symmetrical=true \
    setoptions kind=Mandatory \
    id=o_drbd_bases

pcs constraint colocation add \
    bases with master drbd_bases-clone INFINITY \
    id=c_drbd_bases

pcs constraint order \
    nfs_server-clone then bases INFINITY \
    require-all=true symmetrical=true \
    setoptions kind=Mandatory \
    id=o_nfs_bases

pcs constraint colocation add \
    bases with started nfs_server-clone INFINITY \
    id=c_nfs_bases

plantillas

pcs resource group add templates \
    lvcache_templates lv_templates ext4_templates nfs_templates IPtemplates IPvtemplates 

pcs constraint order \
    promote drbd_templates-clone then templates INFINITY \
    require-all=true symmetrical=true \
    setoptions kind=Mandatory \
    id=o_drbd_templates

pcs constraint colocation add \
    templates with master drbd_templates-clone INFINITY \
    id=c_drbd_templates

pcs constraint order \
    nfs_server-clone then templates INFINITY \
    require-all=true symmetrical=true \
    setoptions kind=Mandatory \
    id=o_nfs_templates

pcs constraint colocation add \
    templates with started nfs_server-clone INFINITY \
    id=c_nfs_templates

grupos

pcs resource group add groups \
    lvcache_groups lv_groups lv_oldgroups ext4_groups ext4_oldgroups nfs_groups nfs_oldgroups IPgroups IPvgroups

pcs constraint order \
    promote drbd_groups-clone then groups INFINITY \
    require-all=true symmetrical=true \
    setoptions kind=Mandatory \
    id=o_drbd_groups

pcs constraint colocation add \
    groups with master drbd_groups-clone INFINITY \
    id=c_drbd_groups

pcs constraint order \
    nfs_server-clone then groups INFINITY \
    require-all=true symmetrical=true \
    setoptions kind=Mandatory \
    id=o_nfs_groups

pcs constraint colocation add \
    groups with started nfs_server-clone INFINITY \
    id=c_nfs_groups

Estas restricciones permitirán que los recursos se coloquen en un nodo preferido.

pcs constraint location lv_groups prefers nas2=50
pcs constraint location lv_oldgroups prefers nas2=50
pcs constraint location lv_bases prefers nas1=50
pcs constraint location lv_templates prefers nas1=50

Utilidades de Pacemaker

Gestionar/No gestionar recurso

Desadministrar recurso drbd.

pcs resource unmanage drbd_templates-clone
Dejar que el clúster controle un recurso drbd nuevamente:
pcs resource meta drbd_templates-clone is-managed=true

Redimensionar volúmenes bajo drbd

Detener el clúster y comenzar drbd manualmente.

pcs cluster stop/standby --all
modprobe drbd
Verifique que los recursos drbd no estén activos (cat /proc/drbd)

CACHÉ: lvcachebases (ro), lvcachetemplates (wb), lvcachegroups (wb)

1.- Caché configurada como solo lectura

eio_cli edit -c groups -m ro

2.- Esperar hasta que no haya sectores sucios (hasta que sea 0)

grep nr_dirty /proc/enhanceio/groups/stats

3.- Eliminar dispositivo de caché

eio_cli delete -c groups

4.- Por ejemplo, reducimos lvcachegroups (600G: nvme0n1p1+/dev/sdf1) y aumentamos lvcachetemplates al nuevo espacio libre.

Reducir nvme0n1p1:

lvreduce -L 100G /dev/vgcache/lvcachegroups Aumentar nvme0n1p1 lvresize -l 100%FREE -n /dev/vgcache/lvcachegroups /dev/nvme0n1p1 Ampliar volumen de caché de plantilla al espacio libre que acabamos de crear. lvextend -l +100%FREE /dev/vgcache/lvcachetemplates

Ahora drbd21 (recurso volumen 0 de grupos) estará en estado 'sin disco'. Esto es normal, ya que rompimos el sistema de archivos drbd interno dentro de los volúmenes redimensionados.

Ahora drbd21 (recurso volumen 0 de plantillas) estará sincronizando, ya que lo ampliamos, pero aún necesita cambiar el tamaño manualmente.

Esto se aplicará a los volúmenes reducidos:

wipefs -a /dev/vgcache/lvcachegroups
drbdadm create-md groups/0
drbdadm up groups
drbdadm invalidate-remote groups/0
Ahora podemos crear nuevamente la caché de grupos EnhanceIO.

Esto se aplicará a los volúmenes ampliados:

drbdadm resize templates/0
Ahora podemos crear nuevamente la caché de plantillas EnhanceIO.

Para los sistemas de archivos que se van a redimensionar, use resizefs para ext4.

Créditos:

https://github.com/stec-inc/EnhanceIO https://www.suse.com/documentation/sle_ha/singlehtml/book_sleha_techguides/book_sleha_techguides.html https://access.redhat.com/documentation/en-US/Red_Hat_Enterprise_Linux/6/html/Power_Management_Guide/ALPM.html